Erlab® CaptairFlow 391 Clean Air Enclosure
Erlab®Earn points on this purchase
| External dimensions (L x D x H) (mm) | 1005 x 615 x 1106 – 1292 |
|---|---|
| Volume of air treated | 220 m3/hr (130 cfm) |
| Sash opening type | Ergonomic Oblong Holes |
| Voltage/Frequency | Connection to main power : 240 V – Internal circuit : 24V-DC/50-60 Hz |
| Enclosure Material | Clear transparent and chemical resistant acrylic panel and electro-galvanised steel coated with anti-acid polymer |
| Filtration Modules | Made of injected Polypropylene |
| Compliance with applicable world safety standards | AFNOR NFX 15-211:2009: France – JG/T 385-2012 : China – SEFA 9 : USA – BS 7989 : England – DIN 12 927 : Germany – EN 1822 : 1998 (HEPA & ULPA) – CE Marking |
| Face velocity meter | Built-in Electronic Hotwire anemometer continuously controlling and monitoring the air face velocity within 0.4 and 0.6 m/s, detects clogging of filters – HEPA or ULPA filters |
| Face velocity at sash opening | 0.4 to 0.6 m/s (80-120 fpm) according to international and local standard (USECHH Reg. 2000) |
| Smart Software | Monitor remotely the safety functions of the Erlab Ductless Fume Hood's performance, change of settings, and events history via computer software and/or Smartphone App |
| Enclosure containment | <0.05 ppm of SF6 detected at the maneque nose level measured according to ASHRAE 110 testing method |
| Molecular filters efficiency | <1% of the PEL-TWA of the handled chemicals released downstream the filtration system |
| Filter revolving technology | 2 identical molecular filters located below and above a fan/detection chamber ensuring no chemical escape when the lower layered filter reached its saturation. Upper layered filter will replace the saturated lower layered filter. Upper layer will be replaced with a new molecular filter. |
| Filter capacity | Erlab chemical listed of over 600 chemicals indicating the molecular filter capacity at 1% of the PEL-TWA of the chemicals. |
| Safety Alert System | Patented "Smart" technology consisting of safety alerts by LED pulsation and coded sounds to express the fan failure, insufficient face velocity or filter saturation/ breakthrough |
| Filters Saturation detectors (option) | Molecode S for saturation detection by solvents |
| Tests Certificates and Reports | Intertek (NFX 15-211) |
| Accessories | (Optional) |
| Carbon Filters for gases and vapours | GF4AS : for organic vapours (acid vapours secondary) |
| HEPA filter for powders | HEPA H14 filtration efficiency : 99.995% according to MPPS method, EN1822 standard |
| Prefilter | 40% filtration efficiency for particles >0.3 micron |
| Stand and base cabinet | Various options of stand with wheels, and base cabinet configures with electrical socket, water, compressed air, sink and faucet. |
| Worktops | Black epoxy worktop with integrated spillage tray |
| Transparent back panel | Clear acrylic panel for easy 360 viewing, natural lighting |